Input data
| Nominal input voltage |
100 V AC ... 240 V AC |
| AC input voltage range |
85 V AC ... 264 V AC |
| DC input voltage range |
90 V DC ... 350 V DC |
| AC frequency range |
45 Hz ... 65 Hz |
| DC frequency range |
0 Hz |
| Current consumption |
Approx. 1.3 A (120 V AC) |
|
0.8 A (230 V AC) |
|
Approx. 1.3 A (for 90 V DC) |
|
Approx. 0.4 A (for 350 V DC) |
| Nominal power consumption |
100 W |
| Inrush surge current |
< 15 A (typical) |
| Power failure bypass |
> 20 ms (120 V AC) |
|
> 20 ms (230 V AC) |
| Input fuse |
3.15 A (slow-blow, internal) |
| Recommended backup fuse |
6 A |
|
10 A |
|
16 A (characteristic B) |
Output data
| Nominal output voltage |
12 V DC ±1% |
|
10 V DC ±1% |
|
15 V DC ±1% |
| Setting range of the
output voltage |
10 V DC ... 15 V DC |
| Output current |
8 A (up to 60°C, 10-12 V DC) |
|
6.6 A (up to 60°C, 15 V DC) |
| Connection in parallel |
Yes, for assembling redundant systems
and increasing efficiency |
| Connection in series |
No |
| Residual ripple |
< 40 mVPP |
| Peak switching voltages
nominal load |
< 50 mVPP (20 MHz) |
| Maximum power dissipation
idling |
2.5 W |
| Power loss nominal load
max. |
12 W |
General data
| Width |
67.5 mm |
| Height |
99 mm |
| Depth |
107 mm |
| Weight |
0.4 kg |
| Operating voltage display |
LED green |
| Efficiency |
> 88 % |
| Insulation voltage input/output |
3 kV (routine test) |
|
3 kV (type test) |
| Degree of protection |
IP20 |
| Class of protection |
II (in an enclosed control cabinet) |
| MTBF |
> 500 000 h in acc. with IEC 61709
(SN 29500) |
| Ambient temperature (operation) |
-25 °C ... 70 °C (> 60°C derating) |
| Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
| Max. permissible relative
humidity (operation) |
95 % (at 25°C, no condensation) |
| Mounting position |
Horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions |
Can be aligned: Horizontal 0 cm,
vertical 5 cm |
| Electromagnetic compatibility |
Conformance with EMC directive 89/336/EEC |
| Emitted interference |
EN 50081-2 |
| Immunity to interference |
EN 61000-6-2 |
| Standard – Safety transformers
for switched-mode power supply units |
EN 61558-2-17 |
| Standard - Electrical
safety |
EN 60950/VDE 0805 (SELV) |
| Standard – Electronic
equipment for use in electrical power installations and their
assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
| Standard - Safe isolation |
DIN VDE 0100-410 |
|
DIN VDE 0106-1010 |
| Standard – Limitation
of mains harmonic currents |
EN 61000-3-2 |
| Standard – Equipment
safety |
GS (tested safety) |
| UL approvals |
UL/C-UL listed UL 508 |
|
UL/C-UL Recognized UL 60950 |
|
UL/C-UL Listed UL 1604 Class I, Division
2, Groups A, B, C, D |
Connection data, input
| Type of connection |
COMBICON screw/plug connection |
| Conductor cross section
solid min. |
0.2 mm2 |
| Conductor cross section
solid max. |
2.5 mm2 |
| Conductor cross section
stranded min. |
0.2 mm2 |
| Conductor cross section
stranded max. |
2.5 mm2 |
| Conductor cross section
AWG/kcmil min. |
24 |
| Conductor cross section
AWG/kcmil max |
12 |
| Stripping length |
7 mm |
| Screw thread |
M 3 |
Connection data, output
| Type of connection |
COMBICON screw/plug connection |
| Conductor cross section
solid min. |
0.2 mm2 |
| Conductor cross section
solid max. |
2.5 mm2 |
| Conductor cross section
stranded min. |
0.2 mm2 |
| Conductor cross section
stranded max. |
2.5 mm2 |
| Conductor cross section
AWG/kcmil min. |
24 |
| Conductor cross section
AWG/kcmil max |
12 |
| Stripping
length |
7 mm |
Signaling
| Output name |
DC OK active |
| Output description |
UOUT > 9 V: High signal |
| Maximum switching voltage |
? 12 V |
| Output voltage |
+ 12 V (signal) |
| Continuous load current |
? 20 mA |
| Status display |
"DC OK" LED green |
| Conductor cross section
solid min. |
0.2 mm2 |
| Conductor cross section
solid max. |
2.5 mm2 |
| Conductor cross section
stranded min. |
0.2 mm2 |
| Conductor cross section
stranded max. |
2.5 mm2 |
| Conductor cross section
AWG/kcmil min. |
24 |
| Conductor cross section
AWG/kcmil max |
12 |
| Screw thread |
M 3 |
|
Block diagram
Diagram
|
Part#: MINI-PS-100-240AC/10-15DC/8
Manufacturer#:2866297
|
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|