Indoor unit with 2 Ethernet interfaces- 19" rack mount, supporting wide range DC input (20 to 60 VDC)
RADWIN’s IDU-C is a carrier grade 1U 19’’ indoor device providing up to 16 E1/T1 (configurable) interfaces and 2 Ethernet ports. Supporting independent clock per each TDM port and dual wide range DC feed, IDU-C is a scalable, easy-to-use solution that is compatible with both RADWIN 2000 and WinLink 1000 radio series.
| TDM Interface |
| Number of Ports |
no TDM ports |
| Type |
E1/T1 configurable by RADWIN Manager |
| Framing |
Unframed (transparent) |
| Timing |
Independent timing per port, Tx and Rx |
| Connector |
RJ-45 |
| Standards Compliance |
ITU-T G.703, G.826 |
| Line Code |
E1: HDB3 @ 2.048 Mbps, T1: B8ZS/AMI @ 1.544 Mbps |
| Latency |
Configurable: 5-20 msec (default: 8msec) |
| Impedance |
E1: 120Ω, balanced
T1: 100Ω, balanced |
| Jitter & Wander |
According to ITU-T G.823, G.824 |
| LAN Interface |
| Ethernet ports |
2x10/100BaseT Ports
Auto-Negotiation (IEEE 802.3u)
Framing/Coding IEEE 802.3 |
| Impedance |
100Ω |
| SFP Interface |
1 Port; Type Fast Ethernet |
| VLAN Support |
Transparent |
| Information Rate |
Configurable in steps of 1Kbps |
| Connector |
RJ-45 |
| Maximum Frame Size |
2048 Bytes |
| Latency |
3 msec (typical) |
| Bridge |
Layer 2, self-learning of up to 2047 MAC addresses (IEEE 802.1Q), Hub/Bridge selectable mode |
| Dry Contact Alarms |
| |
4 Inputs + 4 Outputs; configurable by RADWIN Manager |
| Mechanics |
| Dimensions |
43.6cm(W) x 21cm(D) x 4.4cm(H) |
| Weight |
1.5 kg/3.3 lbs |
| Power |
| Power Feeding |
Dual feeding, -20 to -60 VDC |
| Power Consumption |
< 10 W |
| Environmental |
| Operating Temperatures |
0°C to +50°C / +32°F to +122°F |
| Humidity |
90% non-condensing |
| Safety |
| TUV |
UL/EN/IEC 60950, CAN/CSA 60950 C22.2 |
| EMC |
| FCC |
CFR47 Class B, Part15, Subpart B |
| ETSI |
EN 300 386 (2005), EN 301 489-4 (2002) |
| CAN/CSA-CEI/IEC; AS/NZS |
CISPR 22 |